BK-AA4530F Atomic Absorption Spectrophotometer

BrandBIOBASE

Product originCHINA

Delivery timeWithin 7 days

Supply capacityFactory Direct Supply

Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).

BK-AA4530F Atomic Absorption Spectrophotometer

Features:

* Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).

* Integrated floated optical platform design improves the optical system shock resistance stable.

* Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.

* Position adjusting: the flame burner can be set on the best position automatically.

* Fully automated wavelength scanning and peak searching.

* Complete safety chains protection equipment: warning and automatic safety protection for the wrong burner connection, leakage of the gas, under voltage of air and the abnormal flameout.

* Deuterium lamp and self-absorption background calibration.

* Measuring method: flame absorption method and emission method.

* Result printing: parameter, data result and diagram.

* Data processing: more than 500 data self-storage and cut-off storage, the analyzed result is stored in EXCEL format.



Technical Parameters:

Model

BK-AA4530F

Wavelength Range

190~900nm

Spectral Bandwidth

0.1, 0.2, 0.4,1.0 and 2.0nm

Wavelength Accuracy

≤±0.15nm

Wavelength Repeatability

≤0.04nm

Base Line Stability

≤0.002A/30min (Cu)

Characteristic Concentration

0.02μg/ml/1% (Cu)

Detection Limit

0.004μg/ml (Cu)

Preciseness

≤0.5%

Grating

1800 lines/mm

Inflamer

All-metal titanium burner

Atomizer

Effective glass atomizer

Lamp Stand

8

D2 background Calibration

When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method

Power Supply

220V, 50Hz

Packing Size(W*D*H) mm

860*705*755 (Main instrument); 545*445*1385 (Accessories)

Gross Weight(kg)

105 (Main instrument); 100 (Accessories)

Standard Accessories

Software; Inkjet printer; Oil free Air compressor;

Acetylene reducing valve; Cu Hollow cathode lamp; Air filter

Optional Accessories

Graphite Furnace 4510GF; Hollow cathode lamp(Ag, Au, Ca, Cd, Cr, Fe, Hg, K, Au, Mg, Mn, Na, Ni, Pb, Zn, Sb, etc), Graphite tubes, Recirculating cooling water system, Hydride generator, Autosampler

Flame System:

Acetylene Air Burner

100mm

Ignition Dynamic Baseline Drift

≤0.006A/30min

Characteristic Concentration

≤0.025μg/ml/1%(Cu)

Related Standard Deviation of the Accuracy

≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)

Safety System

Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.

Graphite Furnace(Optional):

Max. Temperature

3000°C

Max Heating Speed

≥2000°C/S

Characteristic Quantity

Cd≤0.5*10T2g Cu≤0.5*1011g

Accuracy

Cu≤3% Cd≤3%

Safety System

Over current protection Low air pressure alarm/protection; Low cooling water flow alarm/protection

Power Supply

220V, 50Hz

Consumption

7000W

Packing Size(W*D*H) mm

740*640*700

Gross Weight(kg)

90