Specifications
Measurement Principle | Photoelectron Yield Spectroscopy (PYS method) |
Measurement WL range | 9.54 ~ 4.0eV(130 ~ 310nm) |
Min. measurement interval | 0.01eV |
Measurement resolution | 10fA ~ 100mA |
Sample chamber | Atmosphere, nitrogen, vacuum compatible/VG65,NW25 port for vacuum pump |
Irradiation light area | approx. 1×3mm ( by slit and vertical aperture ) |
WL resolution ( WL width ) | 0.08eV(4.2nm) * at 256nm |
Sample arrangement | Horizontal , Number of setting sample: 1 pc |
Sample size | Max. 60 x 60mm, Min. 10 x 10mm, Thickness : within 4mm |
Door switch | For safety of Internal applied voltage electrode and for applied voltage for PMT |
Monochromator structure | Nitrogen purge ( light source and high order light cut-filters built in) |
WL drive | Stepping motor, sine bar method ( GPIB control ) |
Focal length | 100mm * for monochromator |
Aperture ratio | F=3.5 * for monochromator |
Mechancial WL range | 0 ~ 400nm * In case of the grating 2400 lines/mm |
WL accuracy | ±1nm * Setting from long WL *WL accuracy & repeatability |
Tubing introduction | IN2 ( Swagelok 1/4), OUT2 ( Swagelok 3/8 ), Relief valve, Flow meter, Stop valve |
PY measuring device | Micro ammeter ( Sub-Femtoamp Remote SourceMeter ) *PY=Photoelectron Yield |
Irradiation intensity detector | PMT( supplied with certified spectral sensitivity data for 130 ~ 310nm ) |
Software control function | System control, photoelectron measuring function,cal. of ionization energy (work function), DOS |
Software save function | Data binary save and redisplay function, save in text |
■ Background measurement and sample measurement can be continuously performed by the sample slide mechanism. Measurement is possible with the preset atmosphere (atmosphere, nitrogen, vacuum) maintained.
■ Ultrahigh sensitivity of 13 digits (10 fA ~ 100 mA) has been achieved with use of PYS method.
■ A port mounting a commercially available dry vacuum pump and composite molecular pump is provided
■ The optional Measurement Range Extension Unit enables the system to measure from 3.4 eV.
Measurement Data
Screen of Measurement Conditions
Ionization energy measurement data of TiO 2 particles [7.4 eV]
Measurement Items
① Background measurement:
The light to be irradiated on the sample is measured in advance with a
photomultiplier, and the number of photons is calculated.
②Sample measurement
Monochromatic light at each wavelength is irradiated to the sample while the
voltage is applied to the sample for the electrons to be released easily.
③ Ionization energy data processing
Y ∝ (hν-I)n
Y= Released numbers of electron measured / numbers of photon irradiated
h Planck's constant
ν Frequency
I Threshold
n depends on density of electrons in the high level edge in the occupied state
of the sample.Only 2 or 3 can be selected in the parameter n.
Standard configurations
●Deuterium lamp 30W, (MgF2 window, natural air cooling )
●Power supply for D2 lamp
●Nitrogen purge type monochromator
●Grating:1200 grooves/mm blazed at 150nm ( MgF2 coating type )
●High order light cut filters and shutter
●Flow meter ( 1 ~ 10L/min)
●Sample chamber (atmosphere, nitrogen atmosphere, and vacuum compatible)
●Sample stage: 62 x 62mm (PTFE, detachable))
●Sample stage slide mechanism (operated outside of sample chamber, travel distance 65mm )
●Plate electrode up-down mechanism ( travel distance 6mm ))
●Standard sample ( Gold leaf Au)
●PMT for measuring irradiation light intensity and high voltage power supply (applied voltage -300V)
●Minute current measurement device for Photoelectron yield measurement
・Minimum range: 1pA Minimum range resolution: 10aA ( when the range is set at 1pA )
・Max. range : 100mA Max. range resolution: 1.0μA ( when range is set at 100mA )
・Noise level: within 0.4 fAp-p(4×10-16 A noise)
●Controller (GPIB control)
●GPIB-USB cable
●Software ( Windows 10 compatible, English )
●PC for controlling the system Note PC Windows 10 64bit
Option
●Measurement range expansion unit ( for 3.4 ~ 7.5eV )
・Grating 2400 grooves/mm blazed at 240nm ( MgF2 coating type )