Specification
Light Source | Deuterium lamp 300w |
Wavelength range | 120 ~ 300nm |
Measurement reproducibility | ±0.3%T *1 |
Wavelength reproducibility | Within 0.1nm |
Sample Size | Minimum 3 x 3 mm ~ Maximum 12 x 12 mm |
Sample thickness | Minimum 1mm ~ Maximum 3mm *2 |
Measurement method | Semi double beam |
Detector | PMT with a salicylic acid soda window |
Setting of display | Scale (Y axis, X axis), Trace(moving cursor) |
Overlay of the spectrum, Delete of spectrum display | |
Data Processing | Smoothing, Arithmetic, 1st ~ 3rd Derivatives, |
Peak processing (Peak Find Peak Height, Peak Area, Data Dump)r |
*1 Under the following conditions: wavelength 120~300nm, Scanning speed 60nm/min, 100% flatness
*2 Specifications of the holder shape and sample numbers to be placed can be customized as option.
■ Transmission measurement in the range of 120 to 300 nm (vacuum ultraviolet region)
■ Nitrogen purge type monochromator enables
high resolution and high stability
■ Ideal for evaluation of special films and
special substrates
Measurement Data
●T% data
of thick synthetic quartz SiO₂
Green Synthetic quartz (t-40mm)
Blue Synthetic
quartz (t-1mm )
Synthetic quartz (SiO2) with thickness of 1mm and 40mm was measured.
The difference in transmittance due to the difference in thickness can be
accurately measured by our unique optical system.
●T% of calcium fluoride (CaF2)
Calcium fluoride (CaF2) used for evaluating optical
crystals and resists was measured.
The wavelength range for F2 laser and ArF laser can be measured with good
reproducibility.
●T% of films for food packaging
Green
Polyethylene
Pink
Polyvinyl chloride
Blue Polychlorinated vinylidene
A film with a thickness of about 10μm was measured. Thin samples such as polymers can be easily measured.
The system can measure continuously from the vacuum ultraviolet region to the ultraviolet region, which is difficult to
measure with a general-purpose ultraviolet-visible spectrophotometer.
●High resolution measurement of air (O₂)
Air was measured at 0.1 nm resolution. The fine structure in the Schumann-Runge
absorption band of oxygen in the air has been clearly measured.
Standard configurations
● Deuterium lamp 30W
● Power supply for Deuterium lamp
● KV-200(nitrogen purge) monochromator
● Sample compartment (for nitrogen purge and vacuum
)
● Transmission measurement sample holder
● PMT(photomultiplier tube) with a salicylic acid
soda window
● Power supply for PMT
● Controller (wavelength drive, filter switching )
● Software (compatible with Windows 7)
● PC for controlling the system
● Instruction Manual
Transmission measurement sample holder
Software
Measurement conditions setting window
Measurement data window
Option
● Vacuum pump
● Various type of sample
holders
● Various gratings
● Salicylic acid soda window