Smile, Smart, Speed
고객의 만족을 위하여 최선을 다하는 기업, 정문사이언스입니다.
고객의 만족을 위하여 최선을 다하는 기업, 정문사이언스입니다.
Multi-channel laboratory micro syringe pump
Multi-channel laboratory micro syringe
pump is widely used in biology and chemistry reaction injection
experiments, long-term animal drug injection experiments, electrospinning,
microfluidic applications and other laboratory microinjection experiments,
etc., through the mechanical device to promote the syringe, to achieve
high-precision, smooth liquid transmission.
Multi-channel laboratory micro syringe
pump main features:
1. Intuitive and easy to use: It adopts
4.3-inch colorful LCD screen with touch function, which is intuitive and easy
to operate.
2. Computer control: can connect the device
to the computer through the USB一RS485 communication
line, and control it through the background software;(optional)
3. Multi-channel independence: select the
split type, multi-channel independent control of the syringe pump, one
controller (touch screen or computer) can complete any combination of multiple
channels;
4. Clean and no worries: connect wireless
mouse remote control work, so that the syringe pump has no hidden troubles to
operate in a ultra-clean working table and other closed environment;
5. multi-factory mode: the program collects
more than 95% of the common syringe models in the market, and can automatically
remember the newly input syringe;
6. DIY function: provide the underlying
dynamic library and programming interface, the user can carry out secondary
development in the personal computer through C#, C++, VB and other programming
languages;
7. Accurate calibration: the program comes
with a flow calibration function to eliminate the volume error caused by
long-term work;
8. Protection setting: protect the syringe
from being damaged by setting the left and right limit positions;
9. Memory function: The system
automatically saves the current operating parameters, and can start working
directly after power-on.
Multi-channel laboratory micro syringe
pump specifications:
Number of Channels |
1~8 |
Infusion volume per microstep |
0.000313Ul(100uLSyringe) |
Applicable syringe type |
0.5uL-1mL |
Advance per microstep |
0.156um |
Flow range |
0.1uL/h-30mL/min |
Max. line speed |
79.4mm/s |
Min. line speed |
7.9um/min |
Maximun pace |
6933 Step/s |
Minimum pace |
0.02533 Step/s |
Woking mode |
Single push mode, push-pull mode |
Linear force |
>20Kgf |
Control accuracy |
Control error <=0.1%, when the
stroke is more than 30% of the full stroke |
Control and display |
4.3 inch LCD colorful touch screen |
Voltage range |
DC18V-DC36V |
Working environment |
temperature 5-40℃, relative humidity <80% |
Mainframe dimensions |
178*44*54(mm) |
Touch screen dimensions |
118*86*34(mm) |
Weight |
0.69kg |