Integrative flue oxygen analyzer
Integrative flue oxygen analyzer can be
widely applied in department of electronic power, metallurgy, heating, building
material and electron, etc to analyze the oxygen content in flue gas from
industrial boiler and furnace. It can also be used in monitoring and analyzing
the oxygen concentration in the combustion gas from large or small-scale
boiler, industrial boiler and combustion devices to achieve the purposes of
reasonable combustion for low oxygen content, lowering the combustion
consumption and loss, stabilizing techniques, improving the products quality
and reducing environment pollution, etc.
Integrative flue oxygen analyzer main
features:
1.Making microprocessor as the core is with
good stability, high reliability and long calibration cycle for features, etc;
2.The auto-compensation system for
temperature could eliminate the influence from environment temperature.
3.The measurement range can be expanded to
0 ~ 40.00%O2 (oxygen-enriched combustion) with the
measurement range shifting automatically;
4.Users can set the upper and lower limits
of oxygen concentration related to 4-20mA output to get the analog output with
higher accuracy;
5.One-way or two-way communication with the
computer can be accomplished through the communication port;
6.The advanced calibration function allow
users to calibrate online.
Integrative flue oxygen analyzer
technical parameters:
Test principle |
zirconia |
Display mode |
4 bits LED display |
Test range |
0 ~ 10/25.00% O2 |
Expanded range |
0 ~ 10/25/40.00% O2 (oxygen-enriched
combustion) |
Resolution |
0.01% |
Accuracy |
≤±1.5%FS |
Repeatability |
≤±1% |
Response time |
T90≤30S |
Analog output |
4~20mA.DC(non-isolated
output, loaded resistance lower than 500 Ohm) 0~5V.DC(non-isolated output, loaded resistance
higher than 10k Ohm) 1 way programmable alarm output (Dry
contact type, maximum load 220VAC/2A) |
Communication port |
RS485 |
Calibration mode |
online calibration |
Power supply |
DC18 ~ 36V/2A |
Operation temperature |
Gauge: -10 ~ +50℃ Probe: low-temperature type,0 ~ 350℃ mid-temperature type,0 ~ 700℃ |
Install Hole Cut |
Φ50mm ~ Φ90mm |
The length of the probe |
1 meter in usual (other length
customizable) |
Serving life |
>3 years (under normal use) |
Install mode |
inserting mount and DN65 standard flange |