Smile, Smart, Speed
고객의 만족을 위하여 최선을 다하는 기업, 정문사이언스입니다.
고객의 만족을 위하여 최선을 다하는 기업, 정문사이언스입니다.
Online close-loop control oxygen analyzer
Online close-loop control oxygen
analyzer has a friendly man-machine dialogue menu, which is intuitive and
convenient to operate.It has a 320×240 dot matrix color LCD display, the
display content is exquisite and clear. The imported zirconium dioxide
sensor is with high measurement accuracy, a rapid response speed and long
calibration cycle for features. The imported built-in sampling pump has
long serving life and is reliable for working.
Online close-loop control oxygen
analyzer main features:
1. The accurate measurement among the range
of ppm ~ % can be met by one-point calibration in the air, making its
calibration simple and convenient;
2. The sampling pump can be turned off
automatically under the condition of gas circuit fault with the functions of
gas circuit blocking alarm and self protection, which could extend the serving
life of sampling pump and sensor efficiently;
3. Power being supplied at a wide range
makes it more suitable for different occasions;
4. No reference gas is needed, and the
analyzer wouldn’t be affected by the oxygen concentration of working around
atmosphere;
5. Adopting RS232 (default) /RS485
(optional) bidirectional communication, it could do one-way or bidirectional
communication with the upper computer;
6. The oxygen concentration in the gas
protection furnace can be controlled automatically without manual control,
making the response immediate;
7. The control error made by the pressure
and temperature of the protection air source can be compensated automatically,
making the components in the system more stable;
8. With the PID parameters self-setting
function, users only need to do the self-setting operation, and the analyzer
could calculate the optimal PID controlling parameter according to the relation
between controlling output and oxygen concentration sampling input to
accomplish the accurate and automatic control to the oxygen concentration;
9. It can save the protection air source at
maximum, decreasing the maintenance cost efficiently;
10. Flow measurement function, with
instantaneous flow collection and cumulative flow display, calculation, storage
(storage once every 10 minutes) and clear (menu clear) function;
11. The meter is mainly used for nitrogen
flow control of SMT main road. When the oxygen concentration in the core
temperature zone is too low and the proportional valve dynamically adjusts the
flow rate, the meter will automatically output a standard flow rate, so that
the oxygen concentration in the furnace is always within the set range ;
12. With proportional valve inlet and
outlet pressure detection function;
13. Bypass protection function, when the
proportional valve fails, the bypass solenoid valve can be automatically opened
in time to keep the shielding gas into the atmosphere protection furnace
without manual intervention, and the response is timely and rapid, reducing the
failure of the proportional valve. Loss;
14. The upper computer software is optional
with the functions of curve display, data saving, parameters setting and so on.
Online close-loop control oxygen
analyzer technical parameters:
Test principle |
zirconium dioxide |
Display mode |
320×240 matrix dot color LCD |
Test Range |
0 ~ 10/100/1000ppm/ 1.00% /
25.00% O2 |
Accuracy |
0~1000ppm/1.00% / 10.00% /
25.00% ≤±1% FS 0~100ppm≤±2% FS 0~10ppm≤±5%FS |
Resolution |
0.1ppm |
Repeatability |
±1%FS |
Response time |
T90≤60S |
Analog output |
4~20mA.DC(non-isolated output, loaded resistance
lower than 500 Ohm) 0~10V.DC(non-isolated output, loaded
resistance higher than 10k Ohm) 2 way programmable alarm output (Dry
contact type, maximum load 220VAC/2A)
|
Other interface |
RS232 (default) or RS485(optional), Ethernet |
Power supply |
AC100 ~ 240V 50/60Hz, power consumption
is less than 60VA |
Environment humidity |
<80%RH |
Sample gas temperature |
-10 ~ +60℃ |
Sample gas flow |
2 ~ 2.5l/min |
Sample gas pressure |
micro-positive pressure, micro-negative
pressure or normal pressure |
Sampling mode |
extraction way |
Background gas |
N2 and inactive gaseous
mixture |
Appearance size |
180mm×266mm×305mm(H×W×D) |
Install hole cut |
182mm×231mm(H×W), In the case of
embedded installation |
Air source pressure |
0.4 ~ 0.8MPa(PV inlet) |
Sampling circuit port |
NPT 1/8 internal thread |
Controlling circuit port |
NPT3/8 internal thread (PV connector) |
Flow range |
0 ~ 65m3/h(normal) |
Flow statistics range |
0~72m3/h (including cumulative
flow function) |
Protection valve flow |
30~60m3/h (air source pressure
4~8bar) |