Induction Heater
|
- Working Voltage: 220V AC, 50/ 60 Hz, Three Phase
- Working Current: 42 Amp (50A breaker required)
- Max. Input Power: 15KW
- Output Frequency: 30 - 80 kHz Adjustable
- Duty Cycle: 80%
- Induction Coil: 95mm(OD) x 85mm(ID) x 50mm(H)
- Auto Heating Time: 1-99 seconds
- Auto Dwell Time: 1-99 seconds
- Auto Cooling Time: 1-99 seconds
- Air Cooling: Rear Fan
- Protection: Automatic water pressure, over-temperature, and
overpower protection
|
Vacuum Chamber
& Graphite Crucible
|
- Quartz Tube
- Half Open Quartz Tube is included with dimensions of 80mm(OD)
x 75mm(ID) x 300mm(L)
- Optional: 100mm(OD) x 92mm(ID) x 300mm(L) Quartz Tube is
available at extra cost
- Vacuum Flange:
- Stainless Steel Flange with high-temperature silicone o-ring and self-tighten structure
- Two valves and vacuum gauge installed on the flange.
- KF25 connector and 1000mm long SS pipe is included for
connecting to the vacuum pump
- High Purity Graphite Crucible: 2.285"(OD) x
1.415"(ID) x 3.05"(Deep) Crucible (79mL) included for
heating and melting
- Complete refractory assembling made of alumina, including
bottom crucible support, crucible holder, and cover.
- One chamber shield is included to protect the chamber from
foreign objects damage as well as containing the exploded piece of the
chamber.
|
Working Temperature
|
- This induction heating system can reach 2000℃ via graphite
heater
- No temperature controller. The temperature will be determined
by sample melting via adjusting current
- If you need accurate temperature control, please order
the induction heating system at CYKY
|
Water Chiller
|
- Temperature range: 5 - 30℃
- Water Flow Rate: 16 L/min
- Water Tank: 12 Liters made of stainless steel
- Note: It is recommended to use the specific coolant to get
the best performance.
- For US customer, 110V water chiller will be included
|
Vacuum Pump
|
- One 156L/m Rotary Vane Vacuum Pump is included
- Rate: 156 L/min
- Max. Power Consumption: 0.4KW / 0.37KW
- For US customer, 110V Vacuum pump will be included
|
Heavy Duty Mobile Cart
|
- Structure: Steel Frame Mobile Cart
- 600mm(L) x 800mm(W) surface for placing Induction Heater
& Quartz Tube with Flange
|
Protective Shield
|
- For Non-UL Certified version, a protective shield made of
phenolic sheets will be provided.
- For UL Certified version, a clear protective shield made of
polycarbonate will be provided.
- The protective shield is to be placed around the quartz tube
to contain the shooting glass shards if accidents were to happen.
|
Product Dimensions
|
- Induction Heater: 18.5"(L) x 12"(W) x 17"(H)
(470mm x 300mm x 430mm)
- Water Chiller: 18"(L) x 8.7"(W) x 28"(H)
(460mm x 220mm x 530mm)
- Heavy Duty Mobile Cart: 600mm(L) x 800mm(W) x 597mm(H)
|
Warranty
|
- One year limited warranty with lifetime support
- Consumable parts such as processing tubes, o-rings, and
heating coil are not covered by the warranty
|
Application Notes
|
- The heater will shut down if over output occurs. Please
reduce coil cycle number or sample size to keep the heater operating
under Max power
- Melting time and temperature are related to materials, the
crucible, refractory insulation, etc. If you do not know whether
the induction heater can melt your sample or not, please contact our
engineer for consulting. Have your alloy's composition, melting
point, and quantity to be melted prepared
- The Induction Melting System is designed for use under
vacuum and low pressure < 0.02 MPa / 0.2 Bar/ 3 PSI and the flow rate for gases should be limited to
< 200 SCCM ( or 200ml/min
- Attention: A pressure regulator must be installed on
your input gas tank and have the output gas pressure set below 3 PSI at
all times after opening the gas tank with the gas maintained in a
continuous flowing condition. Gas build-up with pressure levels
exceeding over 3 PSI may cause irreversible damage to the furnace
chamber.
- Never heat the furnace while the gas release valve is closed
and a positive pressure condition exists within the furnace chamber. The
pressure gauge must be used to closely monitor the chamber condition at
all times during the heating process; please open the gas release valve
immediately once the chamber pressure has reached over 3 PSI to prevent
unforeseeable damages.
|
Net Weight
|
105 kg (230 lbs)
|