Flue oxygen analyzer

모델명 :

상품상세정보

Flue oxygen analyzer has a variety of fault information prompting functions. Self-contained fault detection function can improve troubleshooting efficiency and self-protection ability. PID automatic temperature control circuit, fast and accurate heating, can eliminate the influence of external environment on temperature control. With its own fault detection function, it can improve the efficiency of troubleshooting and self-protection ability. 

Flue oxygen analyzer main features:

1.High-bright OLED active light display, intuitive display;

2.The new zirconia sensor has extremely small drift, fast response and high precision.

3. Add coating on the pipe wall of the sensor contacting the flue gas to reduce the corrosion of the sensor caused by the corrosive gas and extend the service life;

4.The contact part of the oxygen probe and the flue gas adopts a new high-temperature alloy steel, and the oxygen probe can be directly inserted into the furnace chamber below 650℃;

5.Two-point calibration can meet the measurement accuracy of the entire range;

6.The probe and meter are IP54 protection class (except he probe front end);

7.Users can freely set the 4-20mA (default) or 0-10V (optional) output corresponding to the upper and lower limit value, so that users can get higher precision analog output;

8.Standard RS232 (default) or RS485 (optional) communication interface for two-way communication with a computer or other digital communication device.

Flue oxygen analyzer technical parameters:

Measuring principle

 zirconia

Display mode

 128×64 dot matrix OLED

Measuring range

 0.01% ~ 21.00% O2

Measurement accuracy

 <±1.0%.FS

Repeatability

 <±0.5%.FS

Stability

 <±1%.FS (24 hours)

Resolution

 0.01%

Response time

 T90 ≤ 5S

Analog output

4~20mA.DC (default) or 0~10V.DC (non-isolated output, 4 ~ 20mA load resistance ≤ 500 ohm, 0 ~ 10V load resistance > 10K ohm)

2-way programmable dry contact passive alarm output, contact maximum capacity 220VAC/2A

Other interfaces

RS232 (default) or RS485

Calibration method

online   calibration

Power supply

AC220V±10%   50/60Hz, ≤100W

Working temperature

Meter : -10 ~ +50 Probe:0   ~ 650

Background gas

burning fumes (except for strong corrosion and reducing gases)

Hole size

Φ70mm~Φ90mm

Connection method

Meter and probe connection cable (standard 3 meters)

Probe length

Standard length is 1110mm (other lengths can be customized)

Service life

>60 months (under normal use conditions)

Installation method

Probe: plug-in type, meter: wall-mounted